Fan Filter Unit (FFU) 48"x48"¶
- SKU:
EAWAY-FFU-4848 - Category: Cleanroom Equipment
- Evidence source: manufacturer catalog record
-
Data status: catalog-confirmed
-
Subcategory:
ffu - Efficiency class:
H10-H14/U15
Description¶
Fan filter unit (FFU) at 48×48 inch, catalogued in the cleanroom-equipment category for Class 100 duty with H10-H14/U15 efficiency and AC/EC motor. The source publishes the 48×48-inch size (320 mm thickness), an airflow of 4000-5000 CMH, Class 100 cleanliness, H10-H14/U15 efficiency and an 80 °C operating limit, with a galvanised-steel or stainless housing. Our advice: confirm the cleanroom ISO class and coverage, and specify AC or EC motor and voltage. This is a point-source unit; size the fleet to the room, not the room to the unit.
OE cross-reference¶
not published
Technical parameters (spec)¶
| Parameter | Value | Unit | Status |
|---|---|---|---|
dimension |
48×48 (thickness 320) |
inch/mm |
verified |
airflow |
4000-5000 |
CMH |
verified |
cleanliness_class |
Class 100 |
not published | verified |
efficiency_class |
H10-H14/U15 |
not published | verified |
temperature_resistance |
80 |
°C |
verified |
Material¶
| Part | Material | Status |
|---|---|---|
housing |
galvanized_steel / stainless_steel |
catalog-confirmed |
Filter media¶
- Type:
micro_glass_fiber - Efficiency class:
H13/H14/U15 - Grammage: not published
Application¶
| Application | Medium | Status |
|---|---|---|
cleanroom |
cleanroom_ffu |
reference |
MOQ¶
1 pcs (reference)